AST RESEARCH, INC. TECHNICAL BULLETIN # 0930 5-10-94
POWEREXEC 4/25 SLOWING DOWN TO 23 MHz WHILE RUNNING
NORTON’S SYSTEM INFORMATION DIAGNOSTICS
PROBLEM: When the Modify Refresh Rate setting in CMOS Setup is set to
DISABLE, the system processor speed seems to slow down to
23Mhz. This is verified by diagnostic programs such as
Norton’s System Information.
CAUSE: AST 2.22 BIOS introduced the Modify Refresh Rate option to
enhance compatibility with older software programs. Disabling
the Modify Refresh Rate may diminish the performance of the
system by approximately 8%.
SYSTEMS
AFFECTED: All PowerExec 4/25 notebook computers with AST BIOS 2.22 or
higher.
SOLUTION: ENABLE the default CMOS setting for Modify Refresh Rate. When
enabled, diagnostic programs will report that the system speed
is running at 25 Mhz.