AST RESEARCH, INC. TECHNICAL BULLETIN # 1303 9-13-94
WARP CONNECT INSTALL PROBLEM ON BRAVO MS PENTIUMS
PROBLEM:
The Bravo MS Pentium systems may hang on Disk #1 of OS/2 Warp V3.0 during
installation.
CAUSE:
OS/2 Warp Connect uses Read-ahead mode on systems that integrate the
CMD640x PCI IDE chipset on the system board.
SOLUTION:
Disable Read-ahead mode. File PJ19409.ZIP can be found on IBM's BBS
(919) 517-0001 in the "Corrective Service Software" file area.
SYSTEMS AFFECTED:
AST PART NUMBER AND DESCRIPTION
501533-XXX BMS P-60
501534-XXX BMS P-90
501535-XXX BMS P/100
501650-XXX BMS-L P/60
501651-XXX BMS-L P/90
501659-XXX BMS-T P/60
501660-XXX BMS-T P/90
501701-XXX BMS P/75
501754-XXX BMS P/100