AST Research, Inc. Technical Bulletin #1326 10/12/95
BRAVO MS PENTIUM MAY EXPERIENCE PROBLEMS WITH ISA BOARDS
Problem: Various issues, including ISA video adapters displaying
garbled characters; SCSI add-in adapters do not detect SCSI
hard drives.
Cause: The rise time in I/O Channel Ready may not be sufficient
for some ISA adapter cards. The effect is insufficient
initialization or no initialization at all.
Prerequisites: A full backup of all data on the hard drive in the computer
is strongly suggested.
Solution: Replace riser card P/N# 202720-001 with P/N# 202720-001
Rev. A or greater.
Systems
Affected: Part Number Description
________________________________________
501533-XXX BRAVO MS P-60
501534-XXX BRAVO MS P-90
501679-XXX BRAVO MS P-60
501613-XXX BRAVO MS P-90
501765-XXX BRAVO MS P-90
501817-XXX BRAVO MS P-100
501754-XXX BRAVO MS P-100
501701-XXX BRAVO MS P-75
501543-XXX ADV! RMS P-60
501544-XXX ADV! RMS P-90
501710-XXX P III P-75
501861-XXX P III P-100
501926-XXX P III P-133
501695-XXX ADV! 6075P
501713-XXX ADV! 6060P
Instructions: Removal and replacement of system " Field Replaceable
Units (FRU) should only be performed according to
installation procedures approved and prescribed by AST
Research, Inc.